Page 42 Engine Data Management
Pilot Programming Mode
To start Pilot Program Mode, hold both STEP and LF buttons until you
see PROGRAM for two seconds. Then tap the NEXT button to advance
to the desired item in the list. Hold the NEXT button to back up in the list.
Either tap NEXT until you see END. Yes and then tap EXIT or hold both
NEXT and LF to save changes.
First button advances
to NEXT item
Second
button
selects
values
Stays on for two seconds.
Tap REFUEL to change fuel status.
Exits program mode when done.
Scan rate (seconds between
parameters) in the Automatic Mode.
0 disables the Automatic Mode.
NO: When Refuel mode used on EDM,
total fuel used is reset to 0.
YES: accumulate total fuel used rather
than reset to 0 at each refueling. See
page 46.
If equipped with TIT and using ships
original TIT probe change “N” to “Y”.
Tapping 1’s sets the digital display to
one-degree resolution; tapping 10’s
sets 10°. (10° resolution is easier to
interpret the EGTs.)
Tap C to display OAT in Celsius, F to
display in Fahrenheit. Hold STEP and LF
for 5 seconds to ADJUST the OAT
calibration.
Adjust the indicated temperature up or
down by up to 10° using PLUS or MINUS.
For example, OAT3 adjust the OAT 3°
higher.
Hold NEXT and button 2 for 5 seconds
until you see ADJUST HP Constant. Tap
PLUS or MINUSto adjust up or down.
HOLD buttons 1&2 to save. This is where
you do a one time adjustment for % HP
setting.