For Your Safe Flight ............................................. Page 49
1. Make at least three flights of about two to three hours each. Note
the actual fuel used (as determined by topping the tanks) and the
EDM calculation of the fuel consumed for each flight = USD.
Flight
Fuel USED shown by EDM
(total tank - REM)
Actual fuel used by topping
tanks
1
2
3
Total
2. Total the EDM fuel used and the actual fuel used.
3. Record the current K factor here ____________________ and in
the table below.
4. Calculate the Adjustment ratio:
Adjustment ratio = ( / ) - 1
2
5. New K Factor = x (Adjustment ratio +1).
Record the values here:
Date
EDM
fuel used
actual
fuel used
Current K
factor
New K factor
Pilot’s
initials
Setting the K factor
This procedure differs somewhat from setting other parameters. If you
haven’t already done so, start the pilot programming procedure by
simultaneously holding the STEP and LF buttons for a few seconds until
you see the word PROGRAM appear.
1. Tap STEP button to advance to the KF-SET screen KF=29.90 .

Other manuals for J.P. Instruments EDM-900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the J.P. Instruments EDM-900 and is the answer not in the manual?

J.P. Instruments EDM-900 Specifications

General IconGeneral
BrandJ.P. Instruments
ModelEDM-900
CategoryControl Panel
LanguageEnglish