Page 50 Engine Data Management
2. Hold both the STEP and LF buttons for a few seconds until the first
digit flashes (shown here as a larger digit for illustration purposes):
29.00
3. Tap or hold the LF button to change flashing digit: 19.00
4. Tap STEP button to move to next digit: 19.00
5. Tap or hold the LF button to change flashing digit: 18.00
6. Tap STEP button for next digit: 18.00
7. Repeat items 5 and 6 for the remaining two digits.
8. Hold STEP and LF buttons until the parameter is saved.
Fine Tuning the K factor
The K factor shown on the fuel flow transducer does not take into
account your aircraft’s particular installation. Fuel hose diameters and
lengths, elbows, fittings and routing can cause the true K factor to be
different from that shown on the fuel flow transducer. Fine tuning is
accomplished over multiple flights of sufficient duration and repeatable
conditions. Use the process below to calculate and correct the K Factor
to achieve maximum performance. Note: This process adjusts the K.
factor only half of the correction. We recommend this because it
minimizes ‘chasing’ a correction target back and forth.

Other manuals for J.P. Instruments EDM-900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the J.P. Instruments EDM-900 and is the answer not in the manual?

J.P. Instruments EDM-900 Specifications

General IconGeneral
BrandJ.P. Instruments
ModelEDM-900
CategoryControl Panel
LanguageEnglish