Summary

Automatic Water System Pump

Installation and Mounting

Connecting Fittings and Hoses

Connect fittings using flexible hose and clamps to reduce vibration.

Strainer Installation

Install a strainer between the tank and pump inlet to protect valves from debris.

Pump Mounting

Fasten pump to a flat surface, pumphead down if mounting vertically.

Inlet and Discharge Fittings

Install inlet and discharge fittings and secure them with slide clips.

Wiring and Operation

Electrical Safety and Compliance

Wiring must comply with standards and include fuse/breaker to prevent fire.

Wire Size Recommendations

Table specifies wire gauge based on pump voltage and total wire length.

Initial Start-Up Procedure

Fill tank, open faucets, turn pump on, then close faucets nearest the pump.

Continuous Operation Limit

Do not operate the pump continuously for more than 15 minutes.

Technical Specifications and Parts

Model Reference and Specifications

Table lists pump models with voltage, amp draw, fuse size, flow, and pressure.

Exploded View

Diagram illustrating pump components for service and repair.

Pump Service Parts

Lists part numbers for key components like pressure switches and pumpheads by series.

Accessory Port Fittings

Details available snap-in port fittings for connecting hoses and pipes to the pump.

Winterizing Procedures

Draining and Purging the System

Drain the tank and plumbing, then purge pump head to prevent freeze damage.

Antifreeze Recommendations

Use non-toxic potable water antifreeze; avoid automotive types due to toxicity.

Faucet Protection

Leave all faucets open to protect plumbing from potential damage.