operating instructions-Electronic Parameter
PROJECT NAME | date 项目名称 |
CONFIDENTIA
L
14
P 6 2 0/1/2/3 0
Special mode:
0: Normal mode
1: Simply sewing mode
2: Motor initial angle measurement
3: Automatically setting the pulley ratio by the CPU. 4: Automatic test modle (It
has needle stop position of automatic test, running 5s and stopping
3S)
P 6 6 0/2 2
2: safety switch function is on
0: off
P 6 8 0~5000 4000
The upper limit of the maximum speed
P 7 1 0~50 2
Slow release lifter level adjustment, the smaller values and the faster quickly
P 7 6 1~500 60
Back sewing electromagnet full output time ms
P 7 8 10~359 120
Clamp wire start angle
P 7 9 0~359 320
Clamp wire end angle
P 9
8
0~4 4
Voice volume(0~4), 4 is maximum (Restoring the factory will not change)
P 9
9
0/1/2 1
Voice selection 0: Voice Closing, 1: Chinese 2: English Default 1 Chinese
P A
0
1~9999 5000
When the sensor is on and instant shade the sensor, delay time of presser
footer coming down (unit ms)
P A
1
0~600 50
When the sensor is on and shade the sensor, delay time of presser footer
coming down (unit 0.1s)