EasyManua.ls Logo

Jackle maxiMIG 250 - Technical Data

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
maxiMIG 250/300
Operating manual Page 16
12. Technical data
Power source maxiMIG 250 maxiMIG 300
Supply voltage, 50/60 Hz 400V, 3 Phase, +/- 10% 400V, 3 Phase, +/- 10%
Max. drawing of current Imax = 15A, Ieff = 9A Imax = 18A, Ieff = 11A
Fuse 16A slow 16A slow
Maximum power draw 11 kVA 13 kVA
Set-point range 40 - 250A 40 - 300A
Operating voltage 16 – 26,5V 16 - 29V
Open-circuit voltage 21 - 42V 21 - 45V
Voltage steps 12 12
Duty cycle 25 % (40° C) 250A / 26,5V 300A / 29V
Duty cycle 60 % (40° C) 190A / 23,5V 210A / 24,5V
Duty cycle 100 % (40° C) 140A / 21V 170A / 22,5V
System of protection IP 22 IP 22
Insulation category H (180° C) H (180° C)
System of cooling F F
Weight 74 kg 84 kg
Dimensions L x W x H (mm) 880 x 365 x 750 880 x 365 x 750
Noise emission < 70 dB(A) < 70 dB(A)
Wire feed
Wire feed motor with
four-roller drive system 42V, 50W
Wire feed speed 1,0 - 24 m/min
Diameter of wire 0.8 - 1.2 mm
Authorized for welding under increased electrical hazard
Manufactured in accordance with EN 60 974-1 and EN 60 974-10
Generator operation:
The generator must have 30% more power as the welding unit.
Example: 13kVA (unit) + 30% = 17kVA. The generator for this unit must have 17kVA.
A generator with less power will damage the Jäckle welding unit as well as the generator himself
and is disallowed.