EasyManua.ls Logo

Jacuzzi city spa - Suspending the Filtering Cycles; Overheating During Filtering Cycles; Clearray; Hydromassage Activation

Jacuzzi city spa
68 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
NOTE ON THE SILENCE” FUNCTION: where a timer or timer switch
is installed, when activating the “Silence” function (see “Utility func-
tions”) ensure that ltering is not scheduled during the time this func-
tion is active; in any case, the total ltering and “silence” time must not
exceed 24 hours per day.
NOTES
The factory settings are the following:
- cycle duration: 4 hours.
- start delay compared to time “0”: 6 hours.
If no programming is performed, every 24 hours a 4 hour ltering
cycle is performed in any case, and will start 6 hours after the spa is
turned on.
If there is a power outage, the data in the memory is saved, but
the time “0” will become the moment at which the electricity comes
back on. Therefore, it may be necessary to turn the main switch up
the line from the spa o and back on to re-align the cycle start delay
with the memorized parameters.
It is possible to vary the ltering cycle setting parameters at
any time by following the procedure provided at the beginning
of this chapter.
Suspending the ltering cycles
XThe ltering cycle is suspended by activating the pump and/or
by turning on the spotlight. It will restart 10 minutes after the func-
tion is turned o, from the point at which it was stopped. This means
that if 1 hour remained in the cycle when it was interrupted, when it
restarts, it will continue for this time and then stop.
XThe ltering cycle may be suspended by the anti-freeze pro-
tection (“Smart Winter”) or due to overheated water. Refer to the
respective chapters.
Overheating during ltering cycles
During the ltering cycle, if the water temperature exceeds the
set point by more than 1 °C (see the chapter “Setting the water heating
temperature”) and it does not decrease at least 1 °C in the following
3 hours, the cycle will be suspended until the temperature does not
decrease by at least 1 °C below the set point value.
Even if the water temperature is high (due to excessive sunlight,
for example), ltering is ensured for at least 3 hours.
ClearRay ™
The ClearRay™ system uses UV technology which relies on elec-
tromagnetic energy generated by the sun and, by means of a natu-
ral process, reliably and securely improves the disinfecting action,
reducing the need for chemical products to treat the water.
XOperation of the ClearRay™ system is automatic and is de-
pendent upon activation of the circulation pump .
QHydromassage activation
XPress the key once to activate the pump: the relative LED
will light up.
Press the key a second time, the pump will turn o (LED o).
NOTES
If the pump is activated via the button, it will automatically shut
o after 20 minutes unless turned o earlier by the user.
5
pump
spotlight
viewing and adjusting temperature,
parameters, functions
Temperature adjustment LED
heater LED
ltering LED
Spotlight operation LED
Pump operation LED