Motor bearings worn or faulty *
The impeller rubs against the pump body *
Solid bodies in the pump *
Water leakage from shaft Pump mechanical seal worn or defective *
of the pump (rotating joint
between the pump and the motor)
The motor does not start No power Turn on the mains switch
Main switch has tripped Turn on switch
Voltage too low Contact an electrician or the organization
that provides electricity
Circuit breaker has tripped Reset breaker
Incorrect or faulty connections *
Shaft and impeller blocked *
Motor windings burnt *
Faulty contact on motor *
start-up
Water level too low Add water up to the level indicated
(the display presents “LL and the spotlight ashes) in the chapter “Check operations”
The motor stops The function has ended Press the key
again
Overload Let the motor cool,
the problem should disappear.
If it persists, see *
Power supply cables not suitable Consult an electrician
Water level too low Add water up to the level indicated
(the display presents “LL and the spotlight ashes) in the chapter “Check operations”
The “Silence function has been activated See the chapter “Utility functions -
“Silence function
* : This type of repair requires the intervention of qualied personnel.
Contact your Jacuzzi® dealer or an authorised Service Centre.
It is the responsibility of the installer/owner to ascertain compliance with specic local regulations prior to installation. Jacuz-
zi Europe S.p.A. gives no guarantee in this respect and declines all responsibility regarding the compliance of the installation
performed.