49
In the event of malfunctioning and/or situations that require assistance from a Jacuzzi®, Ser-
vice Centre, display keys will ash according to the detected problem, as described below.
XIf necessary, proceed as follows:
- First check that the shower unit is powered (main switch on, electric and hydraulic
system functioning, etc.)
- Then follow the instructions provided for each error type and try to turn the shower
enclosure o and on
. If the error persists, the alarm signal will be displayed when the
shower is turned on or when you try to activate the relative function (contact a Jacuz-
zi® Service Centre).
X(AL1_1) No communication between the control panel and the electric wiring box.
This may occur during the alarm functions, Turkish bath, scale removal cycle and the
hydraulic functions.
HOME SPAmodel: the “alarm” key ashes from white to blue.
BASE AND DREAM model: not available
X(AL1_2) No communication between the control panel and the module.
This may occur when requesting or during an AUDIO function.
HOME SPA model: the audio function keys turn o.
BASE AND DREAM model: not available
X(AL1_3) No communication between the control panel and the light module.
This may occur during the “Cromodream®” function.
DREAM-HOME SPA model only: the "light" key turns o.
BASE model: not available
X(AL2) Temperature probe faulty or disconnected.
This may occur during the Turkish bath” function.
- If the error occurs before starting the Turkish bath, it will start with the maximum tem-
perature set (see relative chapter); once the function has started, the signal will appear on
the control panel at intervals.
HOME SPA model: the "tepidarium", "hammam", "calidarium" and "alarm" keys ash.
If instead the error occurs when the function is in progress, it will be interrupted.
BASE AND DREAM model: not available
BASE AND DREAM (140x90) model: the message is not displayed on the on keypad.
The fault could cause a decrease in performance of the Turkish bath” function.
X(AL3) Timer fault (back-up battery).
This may occur during the scale removal cycle” function.
HOME SPA model: the "alarm" and "water-pitcher" keys will ash from white to blue
and it will not be possible to start the function; if instead the alarm appears when the
function is in progress, it will be interrupted and its start will be inhibited (the number of
Turkish baths carried out will not be reset, see the “Scale removal cycle” chapter).
BASE AND DREAM model: not available
X(AL4_0) Control panel memory fault.
It is not possible to store the start time for the "scale removal cycle" function.
HOME SPA model: the "alarm" and "water-pitcher" keys will ash from white to blue
and it will not be possible to start the function; if instead the alarm appears when the
function is in progress, it will be interrupted and its start will be inhibited (the number of
Turkish baths carried out will not be reset, see the “Scale removal cycle” chapter).
BASE AND DREAM model: not available
Troubleshooting...
electronic functions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi cloud and is the answer not in the manual?

Jacuzzi cloud Specifications

General IconGeneral
BrandJacuzzi
Modelcloud
CategoryBathtubs
LanguageEnglish

Related product manuals