J-200
5. Add Start-Up Chemicals
Add the spa water chemicals as recommended by your authorized
Jacuzzi dealer. See Section 13.0 “Water Quality Maintenance” (page
43) for general guidance.
WARNING: RISK OF POISONING OR DEATH.
Never leave chemicals opened and accessible to anyone.
Use chemicals according to the vendors instructions. Always
store chemicals in a safe and/or locked location. Keep away
from and out of reach of children.
!
6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading of no less than 1.0 ppm free
chlorine or 2.0 ppm bromine. To ensure healthy water conditions,
always maintain a constant sanitizer reading within the levels
recommended on the inside cover of this manual.
7. Set Spa To Heat
To warm spa water to a comfortable temperature, follow
these steps:
The LCD display on the control panel displays the actual
temperature of the spa water. Press either the COOLER ( ) or
WARMER ( ) button once to display the “set” temperature for 5
seconds. If you want the water to heat to a different temperature,
simply press COOLER ( ) or WARMER ( ) within 5 seconds.
The set temperature increases or decreases by 1°F (0.5°C) each
time one of these buttons is pressed.
The heater will turn off when the temperature corresponding to the
thermostat setting is achieved.
Important Heater Details:
The maximum water temperature setting for your spa is 104°F
(40°C) and the minimum setting is 65°F (18°C).
For North America spas connected to a 40 amp service, jets pump
#1 must be set to low speed and jets pump #2 must be turned off to
operate the heater.
Setting the thermostat at maximum will not accelerate the heating
process. This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed “set
temperature,” then turns off. The heater will reactivate after the
water cools to approximately 2°F (1°C) below the set temperature.
19