J-200
the purication system; it has two LED indicator lights, the green
indicating incoming power ow and the red indicating the system
is properly working. CLEARRAY is standard for all models.
Note: The CLEARRAY only runs when pump 1 is on low speed
for an automatic reason, a heat call or a lter cycle.
After a year the bulb must be replaced. A message will appear
on the LCD display when the time allotted has expired. In order to clear
the message, a new UV bulb needs to be installed and the timer must be
reset (page 33).
Note: In order to access the CLEARRAY unit, the front synthetic panel
or stereo panel and right corner panel must be removed.
13.4 CLEARRAY® Lamp Replacement and Quartz Tube
Maintenance
Important: It is MANDATORY that the UV bulb is replaced and the
quartz tube be cleaned every 12 months to maintain optimum
performance.
!
DANGER: TURN THE SPA BREAKER TO THE OFF
POSITION!
!
DANGER: DRAIN THE SPA IF YOU ARE REPLACING OR
CLEANING THE QUARTZ TUBE!
!
WARNING: ALLOW LAMP TO COOL DOWN PRIOR TO
REMOVING FROM QUARTZ TUBE.
!
DANGER: NEVER LOOK AT THE LIT BULB. THIS CAN
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
WARNINGS:
• Do not operate the UV-C emitter when it is removed from the
appliance enclosure.
• This appliance contains a UV-C emitter.
• Unintended use of the appliance or damage to the housing may
result in the escape of dangerous UV-C radiation. UV-C radiation
may, even in little doses, cause harm to the eyes and skin.
• Appliances that are obviously damaged must not be operated.
• Read the maintenance instructions before opening the appliance.
!