I Level of J-MX 07 liquid insufficient
The cycle does not start and the LED for the key on the
recharger flashes.
Aim the remote control at the receiver and hold down the
key for about four seconds. The display will show the
screenshot as indicated.
VV You will need to add the required amount of J-MX 07 liquid
within one minute and repeat the steps described in the chap-
ter on sanitising. If the water level is not restored within 1
minute, the cycle is cancelled.
To return to normal remote control display, press any key.
THE DISINFECTION CYCLE STOPS BY ITSELF
VV First of all, check that the main switch on the power supply
line of the tub is on and that there is not a power outage. Also
make sure you have complied with the instruction provided in
the relative chapter.
If there are any other irregularities, please refer to the following
instructions.
I Defects concerning the electronics box
VV Refer to the paragraph entitled "Hydromassage does not start".
I Decrease of level of water in tub.
This condition may occur in the last minute of the cycle due to
accidental opening of the drain.
The manner in which the anomaly is displayed is the same as in
the paragraph "insufficient water level".
Proceed as follows to restore tub operation:
VV You will need to add the required amount of water within five
minutes from the appearance of the alarm. The cycle will pick up
where it left off and continue until the end. If the level is not re-
stored within five minutes, the cycle will be permanently inter-
rupted with no further warning, since it can be considered
complete.
To return to normal remote control display, press any key.
I J-MX 07 liquid has run out
The anomaly is displayed in the same manner as indicated in
the paragraph "Level of J-MX 07 liquid insufficient".
Proceed as follows to restore tub operation:
VV You will need to add the required amount of liquid within five
minutes from the appearance of the alarm. The cycle will pick up
where it left off and continue until the end. If the level is not re-
stored within five minutes, the cycle is permanently interrupted
and the LED stays on for about sixty minutes, to show that the
cycle was not completed.
To return to normal remote control display, press any key.
To check whether there are any errors in progress, aim the
remote control at the receiver and hold the key down for
about four seconds. If the message appears as shown in the
figure, it means that there is no alarm situation.
To return to normal display operation, press any key.
~4 "
NO
ALARM
OK
16:30
NOTE
ATTENTION
PLEASE
16:30

Table of Contents

Other manuals for Jacuzzi J-Sha Mi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J-Sha Mi and is the answer not in the manual?

Jacuzzi J-Sha Mi Specifications

General IconGeneral
BrandJacuzzi
ModelJ-Sha Mi
CategoryHot Tub
LanguageEnglish

Related product manuals