18
Protection/Défaillance Code
Échec de la sonde de température d’entrée l’eau P 1
Échec de la sonde de température de la serpentine
lors du refroidissement
P 2
Échec de la sonde de température de la serpentine
lors du chauffage
P 3
Échec du capteur de température du gaz de retour
du compresseur
P 4
Échec de la sonde de température ambiante P 5
Protection température ambiante basse P 7
Protection du système haute pression E 1
Protection du système basse pression E 2
Échec de commutateur d’écoulement d’eau E 3
Panne de courant/Phase de pénurie E 4
Cycle de dégivrage
Defrost lamp
flashing
Panne de communication du contrôleur E 8
XIII. Codes de défaillance
5
Remarks:
1. The unit performance will be optimized inside the following temperature range:
Air temp 10˚C - 42˚C (50˚F - 109˚F). The unit efciency will not be guaranteed
out of this range and parameters are different under various conditions.
2. Related parameters are subject to adjustment periodically for technical
improvement without further notice. For details please refer to name plate.
IV. Technical Parameters
Model JA50 JA65 JA85
Nominal Heating Capacity BTU
50 000 65 000 85 000
Nominal Heating Capacity KW
14.65 19.05 24.91
COP
6.14 5.96 5.8
Voltage
AC208, 230/60
Frequency/Phase
60HZ/1PH
Heating Current A
10.17 13.76 19.3
Heating Power KW
2.39 3.2 4.29
Circuit Breaker A
20 30 40
Refrigerant(R410A) lb
3.08 3.75 5.7
Water circulation flow gal/min
21 24 36
Sound Level (10m) Db(A)
29 29 31
1. Technical Parameters