46
7. Use only chemicals and cleaners recommended by Jacuzzi.
8. Remember to keep swim spa covered when not in use. Maintaining proper water levels
assures efficient operaon and efficient electrical usage.
9. Do not expose your swim spa to the sun for extended periods of me as UV rays can
damage the interior surface.
10. Use cauon when removing cover. Before removing cover, assure all locks have been re-
leased to avoid lock breakage and / or cover strap damage.
12.8 Winterizing
Your Jacuzzi swim spa is designed to automacally protect itself against freezing when oper-
ang properly. During periods of severe freezing temperatures, you should check periodically
to be certain that the electrical supply to the spa has not been interrupted. In extreme, bier
cold weather (less than 32
o
F) we recommend that the circulaon pump is set for 24-Hour op-
eraon and that the auto-heang is selected to protect against damage to the swim spa.
If you do not intend to use your swim spa, or if there is a prolonged power outage during peri-
ods of severe freezing temperatures, it is important that all water be removed from the
swim spa and equipment to protect against damage from freezing.
Expert winterizaon of your swim spa is highly recommended; contact your authorized Ja-
cuzzi dealer. In emergency situaons, taking the following steps can minimize damage.
CAUTION: TURN OFF POWER TO SWIM SPA.
1. Follow the direcons for draining the swim spa.
2. Turn the massage / diverter selector(s) into the middle combo posion to allow the wa-
ter in the plumbing lines to drain.
3. Turn the waterfall valve to the open posion to allow the water in the plumbing lines to
drain.
4. Ass the water level drops below the seats, use whatever means necessary to get the wa-
ter out of the recessed seang areas and into the footwell, such as a wet / dry vacuum.
5. Open all the air controls and leave them open unl you resume use of the swim spa.
6. When the water level ceases to drop, use whatever means available to remove any re-
maining water from the footwell, such as a wet / dry vacuum.
7. Remove the equipment-side cabinet panels and locate the drain plugs in the front of
each pump. Remove these plugs to allow for water to drain out of the pumps and heater.