JRT Series Heat Pumps
|
Installation and Operation Manual
Table 1. Jandy JRT Heat Pump Technical Specications
MODEL JRT2000R JRT2500R JRT3000R
VOLTAGE
208/230V/60HZ 208/230V/60HZ 208/230V/60HZ
OUTPUT (80/80/80)*
103,000 BTUs 116,000 BTUs 130,000 BTUs
INPUT (80/80/80)*
4.72 kW 5.23 kW 6.57 kW
COP (80/80/80)*
6.4 6.5 5.8
OUTPUT (80/63/80)**
96,000 BTUs 109,000 BTUs 124,000 BTUs
COP (80/63/80)**
6.1 6.1 5.6
OUTPUT (50/63/80)**
62,000 BTUs 70,000 BTUs 82,000 BTUs
COP (50/63/80)***
4.1 4.1 4.0
RLA (RUNNING LOAD AMPS)
28.3A 29A 32.5A
LRA (LOCKED ROTOR AMPS)
178A 145A 148A
MINIMUM CIRCUIT AMPACITY
38A 39A 40A
MAX OVER CURRENT PROTECTION#
40A 50A 50A
CHILLER FEATURE
YES YES YES
HOT GAS DEFROST
YES YES YES
HEAT EXCHANGER Ti Twisted Coil
COMPRESSOR
Scroll
CABINET ABS
MAXIMUM HEIGHT BELOW WATER LEVEL 10 feet
MINIMUM HEIGHT ABOVE WATER LEVEL 5 feet
OPTIMAL WATER FLOW
42 GPM 48 GPM 57 GPM
MINIMUM WATER FLOW
20 GPM 20 GPM 30 GPM
MAXIMUM WATER FLOW
70 GPM
AIR FLOW
3600 CFM
UNION SIZE 2” PVC Tail Piece / Nut
WEIGHT
232 lbs 242 lbs 252 lbs
* Rated in accordance with AHRI Standard 1160. Test Conditions: 80˚ F Air, 80% RH, 80˚FWater.
** Rated in accordance with AHRI Standard 1160. Test Conditions: 80˚ F Air, 63% RH, 80˚FWater.
***RatedinaccorancewithAHRIStandard1160.TestConditions:50˚FAir,63%RH,80˚FWater.
**** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest standard size breaker.
The breaker size must not be smaller than the Minimum Circuit Ampacity value.