H0569300D
Installation and
Op er a tion Man u al
Installation and Operation Data
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. The electrical supply to this product
must be installed by a licensed or certi ed electrician in accordance with the National Electrical
Code and applicable local codes and ordinances. Improper installation will create an electrical
hazard, which could result in death or serious injury to pool or spa users, installers, or others
due to electrical shock, and may also cause damage to property. Read and follow the speci c
instructions inside this manual.
DANGER
RISQUE DE CHOC ÉLECTRIQUE OU ELECTROCUTION. Cet appareil doit être installé par un
électricien certi é conformément au National Electrical Code et aux normes et règlementations
locales. Une installation incorrecte peut entraîner un risque de problème électrique (choc
électrique ou électrocution) pouvant causer des blessures graves et même la mort des
installateurs et/ou utilisateurs de SPA et Piscines. Lire le manuel et se conformer aux directives.
PELIGRO
RIESGO DE DESCARGA ELÉCTRICA O ELECTROCUTAMIENTO. El suministro eléctrico de
este producto deberá ser instalado por un electricista autorizado o diplomado, de acuerdo al
Código Eléctrico Nacional y a los códigos y normativas que apliquen localmente. Una instalación
inadecuada podría originar riesgos eléctricos y ocasionar la muerte o lesiones graves a los
usuarios de la piscina o spa, instaladores u otros, como consecuencia de una descarga eléctrica,
pudiendo así mismo ocasionar daños a la propiedad. Léa y siga las instrucciones especí cas que
se recogen en este manual.
Jandy
®
Heat Pumps
Model AE-Ti

Table of Contents

Questions and Answers

  • A
    Andre RobertsonAug 18, 2025
    What to do if my Jandy AE-Ti Heat Pump displays HIGH REFRIGERANT PRESSURE?
    • J
      Jonathan Scott PhDAug 18, 2025
      If your Jandy Heat Pump displays a HIGH REFRIGERANT PRESSURE error, first ensure the circulating pump is running and there are no water flow restrictions. Check that all valves are correctly positioned to allow proper water flow to the heat pump. Verify the filter and skimmers are clean and that the water level in the pool is adequate. If the heat pump hasn't been used for a while, try cycling it on and off up to three times. If the problem persists, it's best to call for service.
  • B
    bianca02Aug 21, 2025
    What to do if my Jandy AE-Ti displays LOW H2O FLOW?
    • C
      Cheryl JohnsonAug 21, 2025
      If your Jandy Heat Pump displays a LOW H2O FLOW error, verify that the circulating pump is on and all necessary valves are in the correct positions. Make sure the filter and skimmers are clean, and check the water level in the pool. Temporarily turn off any fountains or waterfalls that bypass the heat pump's water inlet. If the problem continues, call for service.
  • J
    jennifer02Aug 23, 2025
    Why is my Jandy AE-Ti Heat Pump running but not heating the water?
    • S
      Stephen WhiteheadAug 23, 2025
      First, verify that cold air is blowing out of the top of the heat pump. If the heat pump has just been installed or the pool water has cooled significantly, run the heat pump continuously for 24-48 hours. If the heat pump has been in operation for some time, increase the circulating pump time or switch the control board to auto heat function. When heating a spa, make sure no air intake standpipes are open. If the heat pump still does not heat, call for service.
  • B
    Brian SanchezAug 26, 2025
    How to fix a Jandy AE-Ti Heat Pump that won't start and has no control board display?
    • M
      Michelle ToddAug 26, 2025
      If your Jandy Heat Pump won't start and the control board display is blank, the breaker or fuse may have tripped. Reset the breaker or check the fuse. If the heat pump still doesn't run, call for service.
  • J
    Jason HayesAug 28, 2025
    Why is my Jandy AE-Ti leaking water?
    • A
      Aaron PattonAug 28, 2025
      If your Jandy Heat Pump is leaking water, turn it off and then turn the circulating pump on for at least one hour to see if the leak stops. If the water leak stops, it's likely normal condensation. However, if the leak continues after the heat pump has been off for at least one hour, call for service, as there may be a heat exchanger or plumbing leak.
  • G
    gholmesAug 30, 2025
    What to do if my Jandy AE-Ti won't start but the control board display is working?
    • D
      Deborah ChapmanAug 31, 2025
      If your Jandy Heat Pump won't start but the control board display is working, the heat pump may be in a 5-minute delay countdown. Ensure the control board thermostat is calling for the heater to come on by checking the thermostat settings and temperature reading. Also, verify that the heat pump is not in cooling mode.
  • L
    Linda GardnerSep 2, 2025
    What to do if Jandy AE-Ti Heat Pump doesn't run/short cycles, displaying LOW REFRIGERANT PRESSURE?
    • M
      Matthew WilliamsSep 2, 2025
      If your Jandy Heat Pump isn't running or is short cycling and the control board displays a LOW REFRIGERANT PRESSURE error, check that the fan is operating and air is coming out of the top of the heat pump while it's short cycling. If the heat pump does not run at all, call for service.
  • T
    Thomas Bailey DDSSep 5, 2025
    Why does my Jandy AE-Ti not run and display FAULT- HIGH REF PRESSURE?
    • P
      Paul BrooksSep 5, 2025
      The 'FAULT- HIGH REF PRESSURE' message on your Jandy Heat Pump can appear if the circulating pump isn't running, there are water flow restrictions, or the valves aren't properly positioned for water flow. Ensure the filter and skimmers are clean, and check the water level in the pool. This may also occur if the heat pump hasn't been used for a while; try cycling it on and off up to three times to resolve the issue.
  • D
    Douglas AndersonSep 7, 2025
    What to do if my Jandy Heat Pump does not run and shows FAULT- LOW WATER FLOW?
    • B
      brittanywaltersSep 7, 2025
      If your Jandy Heat Pump displays a 'FAULT- LOW WATER FLOW' error, first verify that the circulating pump is on and all necessary valves are in the correct positions. Then, ensure that the filter and skimmers are clean and check the water level in the pool. Temporarily turn off any fountains or waterfalls that bypass the heat pump's water inlet.
  • W
    Whitney DavisSep 9, 2025
    What to do if my Jandy AE-Ti Heat Pump runs but does not heat?
    • M
      Mary WallerSep 9, 2025
      If your Jandy Heat Pump is running but not heating, first verify that cold air is blowing out of the top of the unit. If the heat pump is newly installed or the pool water has cooled significantly, allow it to run continuously for 24-48 hours. If the heat pump has been operating for some time, increase the circulating pump time or switch the control board to Maintain Heat function. Also, if heating a spa, make sure no air intake stand pipes are open.

Summary

General Information

1.2 Consumer Information and Safety

Covers essential safety rules, energy-saving tips, and general consumer information.

1.2.1 Spa;Hot Tub Safety Rules

Details critical safety guidelines for using spas and hot tubs as recommended by the CPSC.

Installation Instructions

2.2 Location Requirements

Covers site selection, clearances, and environmental considerations for heat pump placement.

2.2.2 Clearances

Details required minimum clearances around the heat pump for maintenance and airflow.

2.2.7 Installation of Anchor Clamps

Provides instructions for installing anchor clamps to secure the heat pump to its pad.

Water Connections

Electrical Connections

4.2 Main Power

Details how to connect the main power supply according to electrical codes and unit specifications.

4.3 Bonding

Explains the bonding requirement to ensure safety and compliance with electrical codes.

4.5.1 Connection to a Remote Pool-Off-Spa Selector (3-Wire Connection)

Details installation and configuration for a 3-wire remote pool/spa selector.

4.5.2 Connection to an AquaLink RS Control System or Remote TSTAT (2-Wire Connection)

Instructions for connecting to AquaLink RS or Remote TSTAT systems using 2-wire connection.

Operation

5.1 Initial Start-up Precautions

Essential precautions to take before the initial start-up of the heat pump system.

5.2 Operating the Controller

Explains how to use the heat pump's microprocessor-based controller and its buttons.

5.2.2 Pool Mode - (Normal Heat)

Details how to operate the heat pump in Pool Mode for normal heating.

5.2.4 Spa Mode - (Normal Heat)

Details how to operate the heat pump in Spa Mode for normal heating.

5.6 Water Pressure Switch Adjustment

Provides instructions and precautions for adjusting the water pressure switch.

General Maintenance

6.1 Water Chemistry

Highlights the importance of proper water chemistry and lists optimal ranges for pools and spas.

6.2 Winterizing

Provides critical steps for winterizing the heat pump to prevent damage from freezing.

6.4 Inspection and Service

Guides on regular inspections to ensure safe and efficient operation of the heat pump.

6.4.2 Professional Inspection

Outlines required annual inspections by a qualified technician for safe and efficient operation.

Troubleshooting

8.1 Troubleshooting Guide

Provides a guide to common symptoms and their corrective actions for heat pump problems.

8.2 Diagnostics

Lists diagnostic conditions displayed by the unit and their descriptions for troubleshooting.

LIMITED WARRANTY

Jandy AE-Ti Specifications

General IconGeneral
Compressor TypeScroll
Heat ExchangerTitanium
TypeHeat Pump
Heating Capacity140, 000 BTU/hr
RefrigerantR410A
Voltage230V
Water Flow Rate60 GPM