ADJUSTMENT OF PRESSER BAR DIRECTION AND HEIGHT
The side of the zigzag foot is parallel with the openings for the feed dog in the needle plate when
the presser foot lifter is lowered. There should be a clearance of about 6 mm between the
presser foot and the needle plate when the presser foot lifter is raised.
(1) Remove the face plate (unit), and turn the balance wheel to lower the feed dog below the
top surface of the needle plate.
(2) Open the top cover, and set the pressure dial at “ 3 “.
(3) Raise the presser foot lifter, loosen the set screw of the presser bar bracket, and adjust the
distance between the bottom surface of presser foot and the top surface of needle plate to
6 mm.
(4) Tighten the set screw of the presser bar bracket. Be sure that the presser foot is paralleled
with the opening for the feed dog in the needle plate.
(5) Attach the face plate (unit).
(Note)
For removal and attachment of the face plate (unit), refer to page 2.