EasyManua.ls Logo

Janson Controls FC100-4T-1.5G - No. 1 Timer; No. 2 Timer; Reaching Frequency 1; Reaching Frequency 2

Default Icon
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
Default value 100
Reaching frequency 1
P425
Setting Range:0~Max frequency Unit:0.1
Default value 5.0
Reaching frequency 2
P426
Setting Range:0~Max frequency Unit:0.1
FC100 Series set two groups of frequencies arrive,when output
frequency arrive the setting value of P425 and P426,corresponding
multi-function output terminal is ON. Frequency arrive width is of a
hysteresis loop,which is set by P430
Default value 0
No. 1 timer
P427
Setting Range:0~10.0S Unit:0.1
Default value 0
P428
Setting Range:0~100S Unit:1
No. 2 timer
FC100 series have two timers, when time of the timers reaches setting
value (set by P427 and P428), corresponding multi-function terminal
is ON.
Timer start is controlled by external multi-function input terminal.
Some simple program may be made by using these two timers.
6
Chapter 6 Description of parameter setting
FC100 Series User Manaul

Table of Contents

Related product manuals