P/N:0302-0304C January 2003
V-530/550/560/570
Spectrophotometer
Instruction Manual
V -500 for W indow s
Ò

Table of Contents

Other manuals for Jasco V-570

Questions and Answers

  • B
    Brandi OrtizSep 9, 2025
    What to do if the performance at wavelengths shorter than 320 nm is not stabilized in Jasco V-570 Measuring Instruments?
    • P
      Phillip GloverSep 9, 2025
      If the performance at wavelengths shorter than 320 nm is not stabilized in Jasco Measuring Instruments, set the D lamp to “On”.
  • Y
    youngjaniceSep 12, 2025
    What to do if the baseline is curved greatly in excess of 1% in Jasco V-570 Measuring Instruments?
    • W
      William SmithSep 12, 2025
      If the baseline is curved greatly in excess of 1% in Jasco Measuring Instruments, check if baseline correction is set to “Off”. If it is, set it to “On”.
  • K
    Keith WrightSep 13, 2025
    What to do if the performance at wavelengths longer than 400 nm is not stabilized in Jasco Measuring Instruments?
    • S
      sean54Sep 14, 2025
      If the performance at wavelengths longer than 400 nm is not stabilized in Jasco Measuring Instruments, set the WI lamp to “On”.
  • D
    Dylan GentrySep 15, 2025
    What to do if the light source is changed over from WI to D, the step height on the baseline is more than 1% in Jasco Measuring Instruments?
    • R
      rosaleskaylaSep 16, 2025
      If, when the light source is changed over from WI to D, the step height on the baseline is more than 1% in Jasco Measuring Instruments, check if baseline correction is set to “Off” and set it to “On” if it is. Poor adjustment of the light source mirror can also cause this, so readjust the mirror. Another potential cause is that the sample chamber is not securely fitted, or the beam may be incident upon the cell holder; set the sample chamber in the correct position.

Summary

Safety Considerations

Safety Symbols and Warnings

Explains signal words, symbols, and warning labels for safe operation.

Warning Labels and Handling Precautions

Details warning labels for fuses, grounding, and instrument carrying.

Spectra Manager Software Operation

Manual Overview and Startup Procedures

Describes manual layout, notation, and software startup.

Menu Navigation and Program Exiting

Covers navigation of Spectra Manager menus and program exiting.

Measurement Modes and Procedures

Quantitative Analysis Procedures

Details quantitative analysis, calibration curves, and sample measurement.

Spectrum Measurement Procedures

Explains spectrum measurement, parameter setting, and baseline.

Time Course and Fixed Wavelength Measurement

Covers time course and fixed wavelength measurement modes.

Abs;%T Meter Operation

Describes the Abs/%T meter display and its controls.

System Configuration and Installation

Environment Settings and Diagnosis

Covers hardware settings, diagnosis, and accessories configuration.

Spectra Manager Software Installation

Step-by-step guide for installing Spectra Manager software.

Serial Port Configuration

How to set the serial port for spectrophotometer control.

Jasco V-570 Specifications

General IconGeneral
Photometric Range-4 to 4 Abs
Resolution0.1 nm
Scan SpeedUp to 4000 nm/min
Spectral Bandwidth0.5, 1, 2, 5 nm
Light SourceDeuterium
Wavelength Repeatability±0.1 nm