P/N:0302-0304C January 2003
V-530/550/560/570
Spectrophotometer
Instruction Manual
V -500 for W indow s
Ò

Table of Contents

Other manuals for Jasco V-560

Questions and Answers

  • T
    Taylor RomeroAug 19, 2025
    Why is noise high in Jasco Measuring Instruments?
    • S
      Stephanie ChristianAug 19, 2025
      High noise in Jasco Measuring Instruments can occur for several reasons: * The light may not be correctly hitting the center of the entrance slit; if this is the case, adjust the light source mirror. * The spectral bandwidth might be too small; try increasing it. * The absorption of the solvent on the reference beam side may be too high; replace the solvent with a more suitable one. * The lamp may have deteriorated; replace it with a new one.
  • P
    Patricia GuerreroAug 21, 2025
    What to do if Jasco Measuring Instrument does not operate?
    • L
      Laura SpenceAug 21, 2025
      If your Jasco Measuring Instrument isn't operating, first ensure the power cable is securely plugged into the outlet. If it's disconnected, replug it. If the issue persists, remove the power cable and check the fuse in the main unit. Replace the fuse if it's blown. If the fuse blows immediately after replacement, it indicates a fault in the electrical system.
  • M
    michaelwellsAug 23, 2025
    What to do if the light source changeover from WI to D causes a baseline step height of more than 1% in Jasco Measuring Instruments?
    • A
      Amanda ManningAug 23, 2025
      If you observe a baseline step height exceeding 1% when switching the light source from WI to D in your Jasco Measuring Instruments, there are several potential causes: 1. The baseline correction might be set to “Off”. Check this setting and set it to “On” if necessary. 2. The light source mirror might be poorly adjusted. Readjust the mirror. 3. The sample chamber might not be securely fitted, causing the beam to hit the cell holder. Ensure the sample chamber is correctly positioned.
  • T
    Tina PhillipsAug 26, 2025
    Why is the baseline curved greatly in excess of 1% on Jasco Measuring Instruments?
    • J
      Jennifer MooreAug 26, 2025
      A greatly curved baseline (in excess of 1%) in Jasco Measuring Instruments may be due to the baseline correction being set to “Off”. Check this setting and set it to “On”.
  • M
    Mrs. Jamie Berger MDAug 27, 2025
    How to fix unstabilized performance at wavelengths shorter than 320 nm on Jasco V-560?
    • B
      Brandon ChapmanAug 28, 2025
      If the performance at wavelengths shorter than 320 nm is not stabilized on your Jasco Measuring Instruments, the D lamp might be “Off”. Set the D lamp to “On.”
  • R
    ramosemilyAug 29, 2025
    How to fix unstabilized performance at wavelengths longer than 400 nm on Jasco V-560 Measuring Instruments?
    • M
      mannconnieAug 29, 2025
      If the performance at wavelengths longer than 400 nm is not stabilized on your Jasco Measuring Instruments, the WI lamp might be “Off”. Set the WI lamp to “On.”
  • D
    Dr. John Taylor MDSep 1, 2025
    What to do if WI lamp does not light in Jasco V-560?
    • M
      Michael FisherSep 1, 2025
      If the WI lamp does not light in your Jasco Measuring Instruments, check if the lamp has burnt out. If it has, replace it with a new one.
  • J
    Jacob AndersonSep 3, 2025
    What to do if Jasco V-560 do not operate at all?
    • J
      Joshua VargasSep 3, 2025
      If the Jasco Measuring Instruments do not operate, first, check if the power cable is securely plugged into the outlet; if disconnected, replug it. If the issue persists, remove the power cable and check the fuse in the main unit. If the fuse is blown, replace it. If the fuse blows immediately after replacement, the electrical system is faulty.
  • N
    Nicole KramerSep 5, 2025
    Why is there high noise in Jasco Measuring Instruments?
    • A
      Ann MorseSep 5, 2025
      High noise in Jasco Measuring Instruments can occur because the light is not correctly incident upon the center of the entrance slit. If this is the case, you should adjust the light source mirror. Also, high noise may be caused by a spectral bandwidth that is too small, so try increasing the spectral bandwidth. Another reason can be that the absorption of the solvent placed on the reference beam side is too high, in this case replace the solvent with a suitable one. Finally, high noise may appear because the lamp has deteriorated, you should replace it with a new one.
  • I
    Isabella PerkinsSep 7, 2025
    What to do if the WI lamp does not light in Jasco Measuring Instruments?
    • M
      maldonadoluisSep 7, 2025
      If the WI lamp does not light in Jasco Measuring Instruments, check if the WI lamp has burnt out. If it has, replace the lamp with a new one.

Summary

Safety Considerations

Safety Symbols Explained

Explains signal words like WARNING!, CAUTION, and Note.

Warning Labels on the Instrument

Details warning labels for fuse and ground connections on the instrument.

Instrument Carrying Precautions

Provides weight information and handling advice for safe instrument transport.

Regulatory Statements

CE Notice and Compliance

Indicates compliance with EC EMC and Low Voltage Directives based on technical standards.

FCC Statement for USA

Addresses radio frequency interference compliance for the US market.

Preface and Introduction

Manual Layout and Structure

Describes the manual's 10 sections and their purpose.

Foreword and Notation Used

Explains manual conventions and basic Windows operations for users.

Overview of Spectra Manager

Lists available measurement and analysis programs within Spectra Manager.

Spectra Manager Program Operations

Startup Procedures

Guides on turning on the spectrophotometer, PC, and launching Spectra Manager.

Exiting Programs and Shutdown

Details steps for closing applications and powering off the system.

Spectra Manager Menu Navigation

Explains the main menu structure and options for program navigation.

Quantitative Analysis and Spectrum Measurement

Quantitative Analysis Introduction

Overview of analysis methods, operation flow, and calibration curve creation.

Calibration Curve Creation

Step-by-step guide for creating calibration curves using sample data.

Spectrum Measurement Procedures

Guides on measuring spectra, setting parameters, and handling data.

Quantitative Analysis Program Features

Quantitative Analysis Window and Menus

Details the main window components and available menu functions.

File Menu Operations

Covers saving, opening, printing data, and page setup.

Method Menu Operations

Managing analysis methods, parameters, and calibration curve data.

Edit and View Menu Options

Editing data, customizing display settings for sheets and curves.

Advanced Measurement Modes

Spectrum Measurement

Basic spectral measurement process, parameter setting, and baseline correction.

Time Course Measurement

Measuring sample changes over time at a fixed wavelength.

Fixed Wavelength Measurement

Measuring absorbance or transmittance at specific wavelengths.

Abs;%T Meter

Using the analog meter display for real-time absorbance/transmittance readings.

System Environment and Settings

Hardware Settings

Configuring lamps, wavelength exchange, and lamp operating hours.

Diagnosis and Self-Check

Running system diagnostics to check instrument status and components.

Accessories Setting

Configuring optional accessories for enhanced functionality.

Wavelength Correction

Calibrating wavelength accuracy using deuterium lamp emission.

Installation and Configuration

Spectra Manager Installation

Step-by-step guide to install the Spectra Manager software from disk.

Setting the Serial Port (RS-232 C)

Configuring the communication port for controlling the spectrophotometer.

Jasco V-560 Specifications

General IconGeneral
BrandJasco
ModelV-560
CategoryMeasuring Instruments
LanguageEnglish