12
NOTE
Flux core / Gas less wire don’t use for a long time(more than 3days) need to store sealed.
The recommended electrode for the flux-cord, self-shielded process are 0.8 or 0.9mm diameter spools.
Flux-cord wire is excellent for single-pass lap, fillet and butt welding of thin gauged galvanised and mild steels.
[5]Fit the correct sized Knurled Driver roller
for Gas Less Flux Cored wire
[6]Place wire onto spool holder(spool retaining
nut is top thread) Feed the wire through the inlet
guide tube on to the drive roller
[7-9]Close down the top roller bracket and
clip the pressure arm into place. Apply a
medium amount of pressure to the drive
roller
[10]Remove the gas nozzle
and contact tip from the
front end of the MIG torch
[13/14]Fit the correct size
contact tip over the wire and
fasten tightly into tip holder
[15/16] Select the correct sized wire diameter
and set the welding parameter
[15/16] Select the correct sized wire diameter
and set the welding parameter