3.0 SPECIFICATIONS - XTR-PRO-DV, XTR-ALTIMA A2L
EN
REF FEATURES TECHNICAL SPECIFICATIONS
3.1
Refrigerants EPA Certied to ARI 740-98 for refrigerants, R12, 134a, 22 & 410A
3.2
Safety Designed to meet UL1963, AS standards & EU equivalents
3.3
Power XTR-PRO-DV: 220/240 VAC, 50Hz, 3.6A 115VAC/50Hz, 8A
XTR-ALTIMA A2L: 220/240V VAC, 50HZ, 3.4A
3.4
Compressor 1/2 HP Oil less,AC motor drive
3.5
Cooling Fan/Motor
3.6
Protection High Pressure Switch Cuto at 3500 Kpa Compressor protected
by separate circuit breaker Cooling fan motor thermally protected
80% Cylinder Full Shuto available
3.7
Pressure Low side design pressure 1600 Kpa
High side design pressure 3500 Kpa
3.8
Temperature Operating range 100°C to 400°C
3.9
Case Blow-Moulded, High Impact Strength
3.10
Size L 390 mm X W 250 mm X H 380 mm
3.11
Weight 16 Kg (XTR-ALTIMA A2L - 14 Kg)
Perfomance for XTR-PRO-DV