60
Slideout SyStemS
During this override procedure the motors are not synchronized. Visually
watch the room, and if one side is moving signicantly slower than the other
(or not at all), immediately stop and call your dealer or Jayco Customer
Service.
If the system stalls our before reaching end of stroke OR if the room does not
close and seal tightly, call your dealer or Jayco Customer Service.
2. The controller that has malfunctioned should have a ashing red LED indicating a hall
signal fault (will ash 8 or 9 times).
3. Press the “mode button” six times quickly, then press a seventh time and hold for
approximately 5 seconds.
4. The red and green LED’s will begin to ash indicating you are in override mode.
Release the mode button.
5. Use either a wall switch, or one of the slide room switches located on the command
center panel (depending on the slideout). Press the switch toward the word IN or
RETRACT (printed next to the switch) and hold it until the unit comes in completely.
6. This will allow you to get the recreation vehicle to a service center to have the slideout
malfunction diagnosed.
Manually pushing in the slideout
1. Locate the slideout system controller (refer to previous Step 1; locating the system
controllers).
2. Unplug motor 1 and motor 2 connectors at the bottom of the slideout controller. This
releases the motor brakes for each motor.
3. The slideout room can now be manually pushed in. Larger rooms may require several
people to push or pull them.
4. Keep both sides of the slideout relatively even while pushing/pulling.