73
Sanitizing/Winterizing The Plumbing System
Most oor plans have a factory installed water heater bypass that
enables you to avoid lling the water heater with RV antifreeze.
Bypass valves next to the water heater. Locate the bypass shut
o valve(s) by removing the access door located on the top of the
(driver side) sofa base.
operation allows water to ow into the water
heater. Both hot and cold bypass valve handles should
be pointed toward the water heater connections.
operation diverts the ow of water around
the water heater, keeping water out of the water heater.
Hot water bypass valve handle should point inline with
the (red) hot water outlet line. Cold water bypass valve
handle should point inline with the (blue) cold water inlet
line.
The water heater must be bypassed before adding antifreeze or sanitizing solu-
tion to your water system. Failure to do so could result to damage to the water
heater and/or water lter.