Loading...
The Mite-R-Slide II is calibrated in our factory prior to shipping. You should not have to
make any adjustments to the tool. If you find the gauge is not calibrated to 0° or 45°
precisely please follow these instructions.
STEP A:
Set the gauge to 0° and then place a square against your router table fence.
See Figure 19 and 20. If your Mite-R-Slide II square is not perfectly square
you will see a gap towards the front of your router table or a gap closer to
the Router Fence.
STEP B:
Ensure the gauge is set at the "0°". Loosen the Mite-R-Slide II fence clamping knobs (Part #42), See
Figure 21 and slide the Mite-R-Slide II fence (Part #4) towards the front of the table to expose the first set
screw (Part #41). See Figure 21.
FIGURE 19
FIGURE 20
FIGURE 21
FIGURE 22
9
MITE-R-SLIDE II CALIBRATIONS
CALIBRATING FENCE TO 90°” or (“ on the gauge)