EasyManua.ls Logo

Jet DC-1200-M - 4 Machine Specifications; Remaining Hazards; Technical Data

Jet DC-1200-M
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Readandunderstandtheentireinstructionmanualbefore
attemptingassemblyoroperationofthedustcollector.
Keepthisoperatinginstructionclosebytheproduct,
protectedfromdirtandhumidity,andpassitovertothenew
ownerifyoupartwiththetool.
Nochangestothedustcollectormaybemade.
Dailyinspectthefunctionandexistenceofthesafety
appliancesbeforeyoustarttheunit.
Donotattemptoperationinthiscase,protectthedust
collectorbyunpluggingthepowercord.
Alwaysweartheapprovedworkingoutfit:
‐safetygoggles
‐earprotection
‐dustprotection
Duringthechangingorcleaningofthefiltersit’snecessaryto
useamask(maskwithfiltration).
Alwaysdisconnectthedustcollectorfromthepowersource
(unplug)beforeservicingorchangingfilters.
Waituntiltheimpellerhasstoppedcompletely.
Neverreachintothemachinewhileitisoperatingorrunning
down.

Toreducetheriskofinjuryfrommovingparts,alwayskeep
inletportcoveredwiththeguardprovided.
Hosesorductworkmustbeconnectedbeforeswitchingon
thedust‐collector.
Filterandcollectionbagmustbeinstalledandinproper
condition,beforeswitchingonthedust‐collector
Makesurethatthepowercorddoesnotimpedeworkand
causepeopletotrip.
Donotoperatethemachineundertheinfluenceofdrugs,
alcoholoranymedication.Beawarethatmedicationcan
changeyourbehaviour.´
Keepchildrenandvisitorsasafedistancefromtheworkarea.
Neverleavearunningmachineunattended.Beforeyouleave
theworkplaceswitchofftheunit.
Donotoperatetheelectrictoolnearinflammableliquidsor
gases.
Observethefirefightingandfirealertoptions,forexample
thefireextinguisheroperationandplace.
Donotusethedustcollectorinadumpenvironmentanddo
notexposeittorain.
Donotusethisequipmenttofiltervolatilefumesorsmoke.
Wooddustisexplosiveandcanalsorepresentarisktohealth.
Dustformsometropicalwoodsinparticular,andfrom
hardwoodslikebeachandoak,isclassifiedasacarcinogenic
substance.
Donotstandonthemachine.
Connectionandrepairworkontheelectricalinstallationmay
becarriedoutbyaqualifiedelectricianonly.

Replaceadamagedfilterimmediately.
Replaceadamagedcollectionbagimmediately.
Haveadamagedorwornpowercordreplacedimmediately.
3.3Remaininghazards
Whenusingthemachineaccordingtoregulationssome
remaininghazardsmaystillexist.
Dustcancauseinjuries.
Theuseofincorrectmainssupplyoradamagedpowercord
canleadtoinjuriescausedbyelectricity.
Dangerofexplosionifnotproperlygrounded.
4.MachineSpecifications
4.1Technicaldata
Dustinlet Ø125mm(2xØ100mm)
AirflowØ125 1200m³/h
Vacuumpressure 1880Pa
Collectorbagcapacity 150L
Collectorbagdiameter 500mm
Mains 1~230V,PE,50Hz
Inputpower 1,5kW(2HP)S1
Referencecurrent 7.3A
Extensioncord(H07RN‐F) 3x1,5mm²
Installationfuseprotection 16A
Protectionclass I