5
Technical Data
For Eire Ventilation should be in accordance with ICP 3.
Shelf clearance = Min height of a combustible shelf above the fire.
Shelf depth up to 150mm deep - Minimum height = 300mm
If the shelf depth is greater than 150mm add 50mm to the shelf clearance height for every 25mm
increase in shelf depth.
Side clearance = Min distance from the side of the frame to combustible material = 150mm
Gas supply
a) Installation pipes should be in accordance with BS 6891. Pipework from the meter to the
appliance must be of adequate size. Pipes of a size smaller than the appliance inlet gas
connection should not be used.
WEIGHT (Kg) 7 7 8
HEARTH WIDTH (MIN) 650 650 700
HEAT INPUT kW (GROSS)
16”E 16” 18”
HIGH Manual 7.00 10.00 9.75
LOW Manual 3.60 4.50 4.50
HIGH Remote Control 7.00 XXX 9.75
LOW Remote Control 3.60 XXX 4.50
SETTING PRESSURE AT
MAX. INPUT (COLD)
20mbar ± 1.0mbar
INJECTOR
16”E 16” 18”
Manual 540 700 700
Remote Control 510 XXX 650
PILOT TYPE
Manual
Remote Control
S.I.T. Oxypilot NG9039
S.I.T. Oxypilot NG9079 Split Thermocouple
GAS CONNECTION 8mm o.d. tube
BATTERY
Remote Control
Handset
Fire/Burner
PP3, 9 volts sealed long life Alkaline.
Battery Pack 2xD, 7.2 volts sealed long life Lithium
AIR SUPPLY cm²
16”E 16” 18”
MANUAL & REMOTE CONTROL 0 100 100
GAS TYPE
Natural gas only
GAS CATEGORY
I2H EN437
COUNTRY FOR USE IN
GB / IE