Installation and operation of the Mynx
INSTALLATION & OPERATING INSTRUCTIONS
14
INSTALLATION AND
OPERATING INSTRUCTIONS: Mynx
Ensure that the area to be sealed on the
flue pipe and the flashing is clean and
free from dust, rust, oil and any other
contaminants.
Apply silicone generously, ensuring that
all gaps are covered. The silicone can be
smoothed around the pipe and over the
edge of the flashing, using a wet finger.
NOTE: Before attempting to smooth the
silicone with a finger, first inspect the area
for any protrusions or materials that might
lead to personal injury!
Do a final inspection of the complete
joint. If any possible water leaks are
detected, cover that as described above.
NOTE: The paint is water based, and will
be washed away if it is exposed to rain
before it has dried. The paint needs 24
hours to dry properly.
NOTE: Allow at least 24 hours for both the
paint and the waterproofing paint to dry
before attempting to light a fire