Questions and Answers

  • L
    Lori BenderAug 17, 2025
    What to do if my JLG X700AJ-X23J battery charger shows error code 252 (short-circuit in output)?
    • D
      Danielle MullinsAug 17, 2025
      If the battery charger displays error code 252, indicating a short-circuit in the battery charger output, turn off the battery charger and resolve the short-circuit at the output.
  • Q
    qwoodAug 22, 2025
    What to do if my JLG X700AJ-X23J battery charger shows error code 240 because digital input is open?
    • D
      Debra VelezAug 22, 2025
      If the battery charger displays error code 240, indicating that the digital input is open, the battery charger will stop charging until the digital input closes. Close the digital input to resolve this issue.
  • A
    amandalawsonAug 25, 2025
    What to do if JLG X700AJ-X23J show Inverter Error Code 8 - Watch Dog?
    • B
      Brian PaulAug 26, 2025
      If the JLG Boom Lifts shows Inverter Error Code 8 - Watch Dog, check the control connections and continuity of the electric motor. If they are OK, replace the inverter, because the inverter is not able to activate or turn off the electric motor.
  • B
    Brandon PhelpsAug 28, 2025
    What to do if JLG X700AJ-X23J Boom Lifts show Inverter Error Code 19 - Logic failure #1?
    • R
      Rachel MillerAug 28, 2025
      If JLG Boom Lifts shows Inverter Error Code 19 - Logic failure #1, it is usually a temporary anomaly due to a working condition, caused by an overvoltage or a sudden voltage drop. However, if the anomaly persists, replace the inverter.
  • D
    Debra HamiltonAug 30, 2025
    What to do if JLG Boom Lifts show Inverter Error Code 16 - Aux output KO?
    • C
      cartersandraAug 30, 2025
      If JLG Boom Lifts shows Inverter Error Code 16 - Aux output KO, it is usually a temporary anomaly due to a working condition, caused by electromechanical brake problem. In case the anomaly persists replace the inverter.
  • C
    coxmichelleSep 2, 2025
    What to do if JLG X700AJ-X23J Boom Lifts show Inverter Error Code 8 - Flash Checksum?
    • A
      Adrienne ShepherdSep 2, 2025
      If JLG Boom Lifts shows Inverter Error Code 8 - Flash Checksum, replace the inverter, because the software is corrupted or the inverter is damaged.
  • M
    Miranda BrownSep 4, 2025
    What to do if JLG Boom Lifts show Inverter Error Code 13 - Eeprom KO?
    • H
      Heather BaileySep 5, 2025
      If JLG Boom Lifts shows Inverter Error Code 13 - Eeprom KO, replace the inverter, because there is a hardware or software problem in Eeprom.
  • R
    Robert WoodSep 7, 2025
    What to do if JLG Boom Lifts show Inverter Error Code 18 - Logic failure #2?
    • E
      Emily NguyenSep 7, 2025
      If JLG Boom Lifts shows Inverter Error Code 18 - Logic failure #2, replace the inverter, because there is a fault in the inverter.
  • L
    lindafrostSep 10, 2025
    What causes BMS fault code 02 - Unexpected Voltage in JLG X700AJ-X23J?
    • C
      Cheryl ShepardSep 12, 2025
      BMS fault code 02, "Unexpected Voltage," in JLG Boom Lifts is caused by the BMS failing to identify one cell or being unable to connect it to the discharging resistance. When one cell reaches 3650 mV, the BMS will disconnect the lithium pack, triggering this error.
  • S
    Sharon KellySep 10, 2025
    What to do if my JLG X700AJ-X23J Boom Lifts battery charger shows error code 244 because the mains voltage is too low?
    • A
      Alexander JohnsonSep 12, 2025
      If the battery charger shows error code 244, indicating that the mains voltage is lower than the maximum operating range tolerance, make sure the mains voltage is within the correct operating parameters. The battery charger won’t start charging until the mains voltage returns within the normal operating range.

Summary

SECTION A. INTRODUCTION - MAINTENANCE SAFETY PRECAUTIONS

Safety Precautions

Essential safety guidelines for operating and maintaining the equipment.

SECTION 2. SERVICE PROCEDURE

2.9 EMERGENCY ELECTRIC MOTOR OVERRIDE

Procedure for activating the electric motor in emergency situations.

SECTION 3 - TROUBLESHOOTING AND FAULT CODES

3.1 FAULT CODES

Overview of fault code display and general troubleshooting approach.

BMS Fault Codes

List and description of BMS fault codes for different generations.

Inverter Fault Codes

List and description of inverter fault codes and corrective actions.

Battery Charger Fault Codes

Fault codes and solutions for battery chargers.

JLG X700AJ-X23J Specifications

General IconGeneral
Power SourceDiesel
Jib Length6 ft
Overall Width8 ft
Gradeability - 2WD45%
Engine TypeDiesel
Engine Power74 hp
Fuel TypeDiesel
Platform Length6 ft
Platform Size30 x 72 in
Ground Clearance1 ft
Platform Width2.5 ft

Related product manuals