Code C8
of minor unbalance readings in grams, or ounces.
(gms or oz)
under C3.
Range 3.50 to 20.0 g
Factory-adjusted to 3.5 g
Read out limit, e. g. 3.50 g
Select another limit, e. g. 5.50 g
Range 0.25 to 2.00 oz
Factory-adjusted to 0.25 oz
Read out limit, e. g. 0.25 oz
Select another limit, e. g. 0.50 oz
The selected mode of operation can be transferred to
the permanent memory.
Code C10
permanent memory
0* = No storage
1 = Data are stored in the permanent memory
Store in the permanent memory – a three-tone
signal is given to acknowledge acceptance.
If the mode stored in the permanent memory is to be
changed, enter the desired state (e. g. on or off) for
the mode in question and transfer it via code C10 into
the permanent memory (not possible for code C4).
Code C12
Readings of numbers of measuring runs
Example: 222,123 measuring runs so far performed
(Fig. 7-3).
The following counters can be displayed:
1 = Total number of measuring runs
2 = Number of measuring runs where balance
quality was considered OK
3 = Number of optimizations or minimizations
* = Factory adjusted mode
Range 0.12 to 0.71 oz
Factory-adjusted to 0.18* oz
Select another limit, e. g.: 0.50 oz
• Select Code C8
• Set the value 0.50
• Press ENTER
Range 3.50 to 20.0 g
Factory-adjusted to 5.0* g
Select another limit, e. g.: 5.50 g
• Select Code C8
• Set the value 5.50
• Press ENTER