F4-CVM VAV Terminal Equipment
Controllers Installation Instructions
Application
The CVM03050 equipment controllers are designed for variable air volume (VAV) box applications.
CVM03050 controllers operate on an RS-485 BACnet
®
MS/TP bus as BACnet Advanced Application
Controllers (B-AACs) and integrate into Johnson Controls
®
and third-party BACnet systems.
CVM03050 controllers feature an integral damper actuator, a digital Differential Pressure
Transmitter (DPT) sensor, and a 32-bit microprocessor. The CVM03050-0P model features an
integral potentiometer to sense actual VAV box damper position. These controllers also include an
integral real-time clock, which enables the controllers to monitor and control schedules, calendars,
and trends, and operate for extended periods of time as stand-alone controllers when offline
from the Facility Explorer
®
system network. These controllers connect easily to the wired and
wireless network sensors for zone and discharge air temperature sensing. Their small package
size facilitates quick field installation and efficient use of space without compromising control
performance.
Figure 1: F4-CVM3050
Communications protocols
The CVM03050 controllers can communicate using BACnet MS/TP, N2, or wireless Zigbee
®
. By
default, the CVM controllers communicate using the BACnet MS/TP protocol. The BACnet protocol
is a standard for ANSI, ASHRAE, and the International Standards Organization (ISO) for building
controls.
Part No. 24-10143-01809 Rev. B
2019-05-17
(barcode for factory use only)
F4-CVM03050-0, F4-CVM03050-0P
*241014301809B*

Questions and Answers

Johnson Controls F4-CVM Specifications

General IconGeneral
BrandJohnson Controls
ModelF4-CVM
CategoryController
LanguageEnglish

Summary

Product Overview

Application

Describes the VAV box applications for the controller.

Communications Protocols

Details the communication protocols supported by the controller.

Installation and Mounting

Emissions Compliance

North American compliance statements for FCC and Canadian regulations.

Installation Steps

Guidelines and steps for installing the CVM03050 controller.

Included Parts and Tools

Lists items included and tools needed for installation.

Mounting Guidelines

Procedures and considerations for physically mounting the controller.

Wiring and Connections

CVM03050 Physical Features

Describes the physical characteristics and components of the CVM03050.

Terminal Blocks and Ports

Explains terminal blocks and bus ports for controller connections.

Modular Ports

Information on RJ-12 modular ports for FC bus and SA bus connections.

Supply Power Connection

Instructions for connecting the 24 VAC supply power to the controller.

Termination Diagrams

Visual diagrams for wiring inputs and outputs to the controller.

Wiring Guidelines

General guidelines for wiring inputs, outputs, and communication buses.

Setup and Configuration

Communication Protocol Setup

Steps to configure N2, MS/TP, or wireless communication protocols.

Device Addressing

How to set the unique device address using rotary switches.

EOL Switch Setting

Procedure for setting the End-of-Line switch.

Operation and Maintenance

Controller Commissioning

Procedures for commissioning the CVM03050 controller.

Troubleshooting

Guidance for diagnosing and resolving controller issues, including LED status.

Repair Information

Instructions for unit replacement if the controller fails.

Technical Information

Ordering Information

Product codes for the controller and accessories.

Technical Specifications

Detailed technical specifications for the CVM03050 controller.

Points of Single Contact

Regional contact details for Johnson Controls.