Johnson Controls
5586996-JSG-A-0120 | Start-Up & Operation Guide
25–50 Ton Model Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
G V A 1 M – 1 B 1 A A – 1 A 6 0 A – A 2 4 1 B – F 2 B B H – 4 C 1 A 1 – B K AG 1 – 0 1 0 1 C – 0 1 0 B C – 0 0 0 1
Digits 1–2: Product Brand Name
GV: Johnson Controls
4
Nomenclature
Digit 3: Capacity
A: 25 Ton
B: 30 Ton
C: 40 Ton
D: 50 Ton
Digit 4: Efficiency
1: Standard Capacity, Standard Efficiency
2: Std Capacity, High Efficiency
3: High Capacity, Std Efficiency
4: Std Capacity, Std Efficiency, Low Sound
5: Std Capacity, High Efficiency, Low Sound
6: High Capacity, Std Efficiency, Low Sound
Digit 5: Heat Source
A: Cooling Only
B: Staged Gas Aluminized Burner
C: Staged Gas Stainless Steel (SST)
G: Modulating Gas Stainless Steel
K: Steam Coil
L: Hot Water Coil
M: Electric Heat
Digit 6A: Electric Heat Capacity
0: None
1: Low Heat
3: High Heat
4: Low Heat with Silicon Controlled Rectifier
(SCR)
6: High Heat with SCR
Digit 6B: Natural Gas Heat Capacity
0: None
1: 250 MBH
2: 500 MBH
3: 750 MBH
5: 1,250 MBH
Digit 6C: Hot Water or Steam
Heating Coil Option
0: None
1: Low Heat without Valves
2: Low Heat with Valves
3: High Heat without Valves
4: High Heat with Valves
Digit 7: Unit Type
A: Single Zone Variable Air Volume (SZVAV)
(No Duct Pressure Transducer)
B: Multi Zone Variable Air Volume (MZVAV)
(Duct Pressure Transducer)
Digit 8: Motor Control Options
1: Supply Fan Variable Frequency Drive
(VFD)
2: Supply Fan VFD with Line Reactor
3: Supply Fan VFD with Bypass (Redundant
VFD)
4: Supply Fan VFD with Line Reactor and
Bypass (Redundant VFD)
5: Supply Fan VFD and Return/Exhaust Fan
VFD
6: Supply Fan VFD with Line Reactor and
Return/Exhaust Fan VFD with Line Reactor
7: Supply Fan VFD and Return/Exhaust
Fan VFD with Bypass (Redundant VFD
for Supply Fan and Bypass for Return or
Exhaust Fan)
8: Supply Fan VFD with Line Reactor and
Return/Exhaust Fan VFD with Line Reactor
with Bypass (Redundant VFD for Supply
Fan and Bypass for Return or Exhaust Fan
Digit 9: Voltage
A: 208-230 V 3Ph 60 Hz, Single Point Termi-
nal Block
B: 208-230 V 3Ph 60 Hz, Dual Point Terminal
Block
C: 208-230 V 3Ph 60 Hz, Single Point Non-
Fused DISC
D: 208-230 V 3Ph 60 Hz, Single Point
Terminal
Block, 65KA Short-Circuit Current
Rating (SCCR)
E: 208-230 V 3Ph 60 Hz, Dual Point Terminal
Block, 65KA SCCR
F: 208-230 V 3Ph 60 Hz, Single Point Fused
DISC, 65KA SCCR
G: 460 V 3Ph 60 Hz, Single Point Terminal
Block
H: 460 V 3Ph 60 Hz, Dual Point Terminal
Block
J: 460 V 3Ph 60 Hz, Single Point Non-Fused
DISC
K: 460 V 3Ph 60 Hz, Single Point Terminal
Block,
65KA SCCR
L: 460 V 3Ph 60 Hz, Dual Point Terminal
Block, 65KA SCCR
M: 460 V 3Ph 60 Hz, Single Point Fused
DISC, 65KA SCCR
N: 575 V 3Ph 60 Hz, Single Point Terminal
Block
P: 575 V 3Ph 60 Hz, Dual Point Terminal
Block
Q: 575 V 3Ph 60 Hz, Single Point Non-Fused
DISC
R: 575 V 3Ph 60 Hz, Single Point Terminal
Block,
65KA SCCR
S: 575 V 3Ph 60 Hz, Dual Point Terminal
Block, 65KA SCCR
T: 575 V 3Ph 60 Hz, Single Point Fused
DISC, 65KA SCCR
Digit 10: Return Configuration
A: Bottom Return, Right Outside Air (OA),
Side Exhaust
B: Bottom Return, Right OA, Front Exhaust
C: Bottom Return, Left OA, Side Exhaust
D: Bottom Return, Left OA, Front Exhaust
E: Top Return, Right OA, Side Exhaust (No
Return Fan Available)
F: Top Return, Right OA, Front Exhaust (No
Return Fan Available)
G: Top Return, Left OA, Side Exhaust (No
Return Fan Available)
H: Top Return, Left OA, Front Exhaust (No
Return Fan Available)
J: Left Return, Right OA, Front Exhaust
K: Right Return, Left OA, Front Exhaust
L: Front Return, Left OA, Right Exhaust
M: Front Return, Right OA, Left Exhaust
N: Bottom Return, No OA, No Exhaust Air
(EA) (No Return Fan Available)
P: Top Return, No OA, No EA (No Return Fan
Available)
Q: Left Return, No OA, No EA (No Return
Fan Available)
R: Right Return, No OA, No EA (No Return
Fan Available)
S: Front Return, No OA, No EA (No Return
Fan Available)
Digit 11: Discharge Locations
1: Bottom Discharge, from Discharge Plenum
2: Bottom Discharge, Discharge through Heat
Section
3: Top Discharge, from Discharge Plenum
4: Right Discharge, from Discharge Plenum
5: Left Discharge, from Discharge Plenum
6: Left Discharge, Discharge through Heat
Section
Digit 12: Supply Configuration
A: None
B: Small Blank
C, D: Large Blank
E, G: Large Blank with Final Filter
F:
Small Blank with Humidifier and SST Drain
Pan
H, K: Large
Blank with Humidifier and SST
Drain Pan
L: Small Blank Sound Attenuator
M, N: Large Blank Sound Attenuator
P: Small Blank Final Filter
Q, T: Large Blank with Sound Attenuator and
Final Filter
S, V: Large Blank with Sound Attenuator and
Humidifier and SST Drain Pan
Digit 13: Final Filter Options
1:
MERV 15 Bag Final Filters with 2-inch
MERV 8
Filters
2: MERV 14 Rigid Final Filters with 2-inch
MERV 8 Filters
3: MERV 17 High Efficiency Particulate Air
(HEPA) Final Filters with 2-inch MERV 8
Filters
4: MERV 14/15 Filter Rack (No Filters)
5: HEPA Filter Rack (No Filters)
6: None
Digit 14: Final Filter Control Op-
tions
0: None
1: Combined Pre and Post Filter Transducer
2: Separate Pre and Post Filter Transducer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls GVC Series and is the answer not in the manual?

Johnson Controls GVC Series Specifications

General IconGeneral
BrandJohnson Controls
ModelGVC Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals