P/N 34-636-02537, Rev. A
10
Flow rate settings | Réglages du débit | Ajustes del caudal | Einstellungen für
Durchflussmenge | Impostazioni della portata | Instellingen van de stroomsnel-
heid | Nastavení průtoku
Table 5: VP10xHxx and VP10xJxx
Pre-setting the maximum flow | Préréglage du débit maximal | Ajustes del caudal
máximo | Voreinstellen des maximalen Du chflusses | Preimpostazione della
portata massima | Maximumdebiet van tevoren instellen | Přednastavení maximál
-ního průtoku
3
2
1
1
2
3
VP10xHAA VP10xHDA VP10xHDC VP10xJAJ VP10xJDB
Pre-setting Flow l/h Flow l/h Flow l/h Flow l/h Flow l/h
9 150 450 850 1000 1850
8 133.5 408 774 897 1734
7 114 358 689 782 1548
6 99.5 281 606 678 1320
5 85 219 496 564 1080
4 71 179 393 442 846
3 55 135 331 359 624
2 39.5 94 265 278 492
1 19 53 157 154 276
0.5 9 32 62.5 45 174
0 0 0 000