SM-18003
SERVICE MANUAL
INVERTER-DRIVEN MULTI-SPLIT SYSTEM
HEAT PUMP AIR CONDITIONERS
Service Manual
< Indoor Units >
●MiniCassette
(H,Y,C)ICM008B21S
(H,Y,C)ICM012B21S
(H,Y,C)ICM015B21S
(H,Y,C)ICM018B21S

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls YICM008B21S and is the answer not in the manual?

Johnson Controls YICM008B21S Specifications

General IconGeneral
BrandJohnson Controls
ModelYICM008B21S
CategoryAir Conditioner
LanguageEnglish

Summary

SERVICE MANUAL

INVERTER-DRIVEN MULTI-SPLIT SYSTEM HEAT PUMP AIR CONDITIONERS

General overview of the manual's content and system type.

1. Introduction

2. Important Safety Instructions

Critical safety precautions and guidelines for operating and servicing the equipment.

Installation Precautions

Refrigerant Precautions

Electrical Precautions

1. Installation

2. Operation

3. Troubleshooting

3.1 Initial Troubleshooting

Basic diagnostic steps to identify system problems.

3.1.1 Checking Electrical Wiring and Power Supply

Procedures for verifying electrical connections and power supply integrity.

3.1.4 Checking Wired Controller

Detailed guide on checking wired controller functions and status.

3.2 Troubleshooting Procedures

Systematic approach to troubleshooting system faults.

Alarm Code Indication of Wired Controller

Explains how alarm codes are displayed on the wired controller.

3.2.1 Alarm Code Table

A comprehensive list of alarm codes, their causes, and categories.

3.2.2 Troubleshooting Using Alarm Codes

Step-by-step troubleshooting based on specific alarm codes (e.g., Float Switch).

3.2.2 Troubleshooting Using Alarm Codes (continued)

Troubleshooting steps for communication failures between units.

Alarm Code 11

Diagnosing issues related to the Inlet Air Thermistor.

Alarm Code 12

Diagnosing issues related to the Outlet Air Thermistor.

Alarm Code 13

Diagnosing issues related to the Liquid Pipe Thermistor.

Alarm Code 14

Diagnosing issues related to the Gas Pipe Thermistor.

Alarm Code 19

Troubleshooting for the Indoor Fan Motor protection device.

Alarm Code 31

Addressing incorrect capacity settings for units.

Alarm Code 35

Troubleshooting incorrect indoor unit numbering.

Alarm Code b0

Resolving incorrect unit model code settings.

Alarm Code b1

Correcting incorrect unit and refrigerant cycle number settings.

3.2.3 Abnormalities of Devices

General troubleshooting for various device malfunctions.

3.2.3 Abnormalities of Devices (continued)

Troubleshooting heating radiation sensor behavior.

3.4 Test Run

Essential steps and checks for performing a test run after installation.

3.4.1 Test Run Using Wired Controller

Detailed procedure for conducting a test run using the wired controller.

3.4.1 Test Run Using Wired Controller (continued)

Checking procedures for abnormalities during test run.

4. Maintenance

5. External Input/Output and Function Setting

6. Field Work Instructions

6.1 Caution for Refrigerant Leakage

Critical safety information regarding refrigerant gas leaks.

6.2 Modifications of Charging Refrigerants Other than Those Specified by Johnson Controls

Warnings against using non-specified refrigerants due to safety risks.