47
A.0500.301/314.C – IM-TW/10.00 GB (0401)
0082
0083
0085
0082
0083
0085
0890
4.7.8.2 Single mechanical seal with flushing
1. Fit lip seal (0890) and O-ring
(0085) in the stationary part of
the seal.
2. Place the stationary part of the
seal, O-ring and spring in the
rotor case.
Ensure that the pin in the rotor
case fits into the groove in the
stationary part of the seal.
3. Put O-ring (0083) on the
stationary seal face. Place the
stationary seal face with
O-ring into the rotor case.
Ensure that the pins in the
stationary part of the seal are
fitting into the grooves in the
stationary seal face.
4. Put O-ring (0082) on rotating
seal face. Place the rotating
seal face with O-ring into the
rotor.
Ensure that the pins in the rotor
are fitting into the grooves of
the rotating seal face.