2. Specification
32
b) Switching SW connection
Recording modes can be selected by connecting the switching SW of the
following specification to the dry contact input (PI_1 and PI_2 of TB406) of
Recording Control Unit (RCU).
¾ AUTO mode: Images of CH to which the synchronized signals
are outputted are automatically selected and
recorded. If the synchronized signals are
outputted from both CH1 and CH2, CH1 has the
priority to be selected.
¾ CH1 recording mode: Images of CH1 are forced to be recorded.
If no images are inputted to CH1, the image
data will not be recorded.
¾ CH2 recording mode: Images of CH2 are forced to be recorded.
If no images are inputted to CH2, the image
data will not be recorded.
PI_1TB406 PI_ 2TB406 RADAR Recording Mode
OPEN OPEN AUTO
OPEN CLOSE CH1 record
CLOSE OPEN CH2 record
When in operation by AUTO mode, the objective radar images will
be recorded if the power of nonoperational radar is turned off. If
the nonoperational radar is set standby, outputting radar images is
not stopped and therefore, only the X-band radar screen without
any echoes will be recorded.
c) Continuous AUTO mode
When the switching SW is not connected and two radars are connected,
images will be recorded continuously by AUTO mode.