EasyManua.ls Logo

JRC JHS-183 - Page 66

JRC JHS-183
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATIONS
3-16
(A) DATA2
Connector which is connected to the NQE-5183 connection box
Connect the data cable (CFQ-9193A/D/F).
No. Name No. Name No. Name
1 AUX4; TX-A 10 AUX2; TX-A 19 AUX3; GND-ISO
2 AUX4; TX-B 11 AUX2; TX-B 20 ALR_OUT_NC
3 SENSOR3; RX-A 12 AUX2; RX-A 21 ALR_OUT_COM
4 SENSOR3; RX-B 13 AUX2; RX-B 22 ALR_OUT_NO
5 SENSOR3; GND-ISO 14 AUX2; GND-ISO 23 ACK_IN+
6 NSK_24V 15 AUX3; TX-A 24 ACK_IN-
7 GND 16 AUX3; TX-B 25 GND
8 SENSOR4; RX-A 17 AUX3; RX-A 26 GND
9 SENSOR4; RX-B 18 AUX3; RX-B
(B) PILOT PLUG
Connector which is connected to the Pilot PC
Connect the CFQ-9173A to extend.
No. Name No. Name
1 TX-A 6 RX-B
2 NC 7 NC
3 NC 8 NC
4 TX-B 9 GND-ISO
5 RX-A NC; Non-Connection
(C) Terminator
Terminator selector switch for Sensor 1-3
Initial setting is all ON.
No. Name
1 SENSOR1
2 SENSOR2
3 SENSOR3
4 NC
1
2
25
26
OFF
ON