4-7 Chapter 4 Menu Settings and Configurations
4
3. Touch the center of the target marks at the four corners of the screen.
Touch the center of the target marks at the four corners in the order from 1 to 4.
The following screen is displayed.
4. Draw a graphic or a character for validation by touching the screen.
5. Confirm the graph or the character:
Calibration is completed. Close the [TOUCH CAL] menu by touching the [ACCEPT] button.
The touched position does not match the position of the graphic or character:
Restart calibration. Touch the [AGAIN] button and start again from step 2.
Note: If the calibration would take over one minutes, after return to the normal screen the
DISPLAY COMM FAILalert would occur. This is not the system malfunction.