7.4    ADJUSTMENT 
ņ42 
7 
yyy
yyyy
  Procedure    1  Hold down [RADAR MENU] key. 
 
The Code Input Menu will appear. 
 
2  Press [0] key. 
 
3  Move the cursor onto the “ENT” button 
in the Code Input menu, and press 
[ENT] key. 
 
The Adjust Menu will appear. 
 
4  Press [8] key while the Adjust Menu is 
open. 
 
The SP/TT INIT Setup Menu will appear. 
 
5  Press [2] key. 
 
The TT Menu will appear. 
 
6  Press [1] key. 
 
The window for setting vector constants will appear. 
 
7  Select the value you want to set, pressing the numeric keys [1] to [8]. 
 
To improve vector follow-up performance, increase the set value. 
To stabilize vectors, decrease the set value. 
 
 
 Exit   1  Press [RADAR MENU] key. 
 
The Main Menu will reappear. 
 
 
[II] Quantization Level Adjustment (Video Level) 
 
Use the target tracking function (TT) to adjust the level of the signal to be recognized as a target. If a small 
value is set, even weak target signals will be input to the target detection circuit of the target tracking function. 
However, many unnecessary signals are also input, which may cause unstable target acquisition or tracking. It 
is important to set a value four or five greater than the value with which unnecessary signals are detected. 
The quantization level is adjusted to an optimal value, so do not change it carelessly. 
 
 
 
CAUTION 
 
 
 
 
 
Do not change the set quantization level carelessly. 
If the level deviates from the proper value, the TT 
acquisition and tracking functions will deteriorate. 
Otherwise, this may cause accidents.