EasyManua.ls Logo

JRC JMA-5220-7 - Personal Information (Pin Setting)

JRC JMA-5220-7
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3130
3
3.11 USE FUNCTION SWITCH
y
y y
Load PIN Data
1.
2.
3.
4.
5.
0. EXIT
3.11.5 Personal Information (PIN Setting)
The operation status of the radar is recorded. If the system is operated by more than one operator, the
operators can register operation status as suitable for them and call the status. Operation status for up to
five operations can be registered, and a name can be assigned to each status. (Up to 10 alphanumeric
characters)
* Data stored as personal information
Day/Night mode setting
Brilliance
Alarm volume
Vector length/mode
Various types of image processing (IR, ENH, PROC, FUNC)
[1] Calling Operation Status (Load PIN Data)
Procedures 1 Press [RADAR MENU] key twice.
Press [8] key.
The Radar Sub Menu will appear.
2 Press [1] key.
The PIN Setting Menu will appear.
3 Press [1] key.
The Load PIN Data Menu will appear.
4 Select the item you want to load,
pressing the numeric keys [1] to [5].
The Load Execution Check Menu will appear.
Select “Yes” for loading.
Exit 1 Press [RADAR MENU] key.
The Target Information Display Menu will
reappear.

Table of Contents

Related product manuals