– 5 –
1. Fix the throat plate auxiliary
cover
so that is higher than
the throat plate
(within 0.3
mm). When it is lower than
the throat plate
, needle
breakage or the like due to the
defective feed will be caused.
2. Conrm by putting a ruler or
the like that the throat plate
auxiliary cover
is horizon-
tally installed. If not, throat
plate auxiliary cover
and
lower plate
come in contact
partially with each other, and
abnormal worn-out will be
caused.
3-4. Installing the panel
1) Open cover
and remove cable
once.
Then connect it again to the panel on the top
surface of the table after passing it through the
hole in the table.
2) Fix operation panel installing plate
to an op-
tional place on the table with two wood screws
.
Install the panel at the position where
X-move cover or head grip does not
interfere with it since breakage of the
panel will be caused.
Installing the IP-420
Within 0.3 mm