EasyManua.ls Logo

JUKI DDL-8700 - Electrical Cord Connection Guide

JUKI DDL-8700
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Following connectors are prepared when loosening the front cover fixing screws A of SC-500 and opening the
cover. Connect the machine head connectors to the positions corresponding to each other so as to fit the
devices mounted on the machine head.
WARNING :
To prevent personal injury caused by abrupt start of the sewing machine, carry out the work after
turning OFF the power switch and a lapse of 5 minutes or more.
To prevent damage of device caused by maloperation and wrong specifications, be sure to connect
all the corresponding connectors to the specified places.
To prevent personal injury caused by maloperation, be sure to lock the connector with lock.
As for the details of handling respective devices, read carefully the Instruction Manuals supplied
with the devices before handling the devices.
6. Connecting the cords
A
9
2
3
1
4
5
!0
7
!2
OPC circuit board A (asm.)
!3
A
Front cover
6
8
!1
!4
!5
!6
1 CN30 Motor signal connector
2 CN32 Machine head connector
3 CN33 Needle bar position detector connector
4 CN36 Machine head solenoid connector
5 CN37 Presser foot lifter solenoid connector
6 CN38 CP-160 panel connector
7 CN39 Standing machine pedal connector
8 CN40 Signal for extension connector (For the details, refer to Engineer's Manual.)
9 CN51 Not used
!0 CN52 Not used
!1 CN53 Bobbin thread remaining amount detection solenoid connector
!2 CN189 External interface signal connector
!3 CN59 Bobbin thread count-up output connector
!4 CN55 Material end detection sensor (ED) connector
!5 CN58 Standing machine pedal connector
!6 CN57 Bobbin thread remaining amount detection sensor connector