28
(15) Position of the thread tension
Standard Adjustment
(16) Position of the pre-tension
Standard Adjustment
Striking face on the
machine arm
Thread tension controller
Setscrew nut 1
Almost in parallel to
the machine arm
Thread should enter the
rotary disk straight.
Fig. 2 Orientation
Fig. 1 Longitudinal position
Thread tension controller
1
* Felt of the thread tension
controller is a consumable part.
Replace it when it is consumed.
Part No. of felt : 22528509