EasyManua.ls Logo

JUKI MO-6700D Series - 3. STANDARD ADJUSTMENT; (6) Position of the upper looper guide

JUKI MO-6700D Series
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 10 –
MO- 6704D - 0E to 0F - 4 H
MO- 6714D - BB6 to BE6 - 30P
BD4 to BE4
BD6 to BE6
MO- 6716D - - 30P
D
F
(6) Position of the upper looper guide
Vertical position : To be in close contact with the frame guide surface.
Laternal position : To be pressed against the upper looper guide support gauge .
13131909 13132006
Model
Dimension
G
MO- 6714D - - 4 H
(Unit : mm)
(Unit : mm)
Model
Dimension
G
(Unit : mm)
7 5.5
6
6.3 4.7
5.8
5.8
6.3
5.8
5.8
6
G
Marker dot
Frame guide surface
MO- 6716D - - 4 H
Standard Adjustment
Upper looper guide
support gauge
1-needle overlock
machine
2-needle overlock
machine
Safety stitch
machine