EasyManua.ls Logo

JUKI MO-6700D Series - 3. STANDARD ADJUSTMENT; (10) Adjusting the height and clearance of the needle guard

JUKI MO-6700D Series
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 18 –
(10) Adjusting the height and clearance of the needle guard
1) For 1-needle or 2-needle overlock machine
The overlock machine has two needle guards,
A
and
B
.
The needle guard
B
should be located 1 mm below the throat plate bottom surface.
2) For safely stitch machine
The safely stitch machine has four needle guards,
A
,
B
,
C
and
D
. The needle guards
A
and
B
are
positioned in the same manner as those for the overlock machine.
The needle guard
C
should be positioned 5 mm below the throat plate bottom surface.
Needle guard
A
Needle guard
B
Throat plate
1 mm
0.1 mm
B
Throat plate
5 mm
B
0.1 m
m
D
C
(Traveling needle guard)
A
Standard Adjustment
Light
touch
the
needle
guard
Lightly touches

Table of Contents