– 26 –
1) Lower knife
2) Upper knife
3) Overedging width
Overedging width can be adjusted from 1.6 to 6.4 mm.
(16) Positioning the upper knife arm shaft
(17) Positioning the upper and lower knives, and available overedge widths
The upper knife shaft should be positioned 34 mm above the top surface of the throat plate when it is at its
highest position.
34mm
Lower knife
Throat plate
Standard Adjustment
Standard Adjustment
Upper knife
0.5 to 1 mm