− 1 −
(1) SC-500
Electric equipment corresponding to new servo motor (for export)
1. SPECIFICATIONS
(1) Features
1) Voltage changeover function of single phase 100 to 120V/3-phase 200 to 240V is provided. (Adapting to
a part of specifications only)
The control box with voltage changeover function can be used either for single phase 100 to 120V or for
3-phase 200 to 240V by replacing the power cord up to the power switch and setting the voltage
changeover connector inside the control box.
2) The operation panel is assembled in the control box as standard and it is possible to operate the machine
with the single unit of the control box.
By connecting the optional operation panel, CP-160, function and operability are further improved.
3) The conventional JUKI optional devices can be used without any adjustment.
However, it is necessary to separately purchase the optional circuit board.
Supply voltage Single phase 100 to 120V 3-phase 200 to 240V Single phase 200 to 240V
Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
Operating temperature range Temperature : 0 to 40˚C Temperature : 0 to 40˚C Temperature : 0 to 40˚C
Operating humidity range Humidity : 90% or less Humidity : 90% or less Humidity : 90% or less
Power consumption 390VA 390VA 390VA
(460VA when LZ-228* is used) (460VA when LZ-228* is used) (460VA when LZ-228* is used)
6 Control box classification
S JUS (LA) : Single phase 100 to 120V PFL
D JUS : 3-phase 200 to 240V PFL
K General export : Single phase 200 to 240V PFL
N CE : Single phase 200 to 240V PFL
U China : Single phase 200 to 240V PFL
7 Electric equipment type classification
S Standard
9 Destination spec. classification
A Standard
10 Accessory spec. classification
A Standard
11 Delivery voltage classification
4 200 to 240V
4 Voltage classification
D 3-phase 0 to 340V DC
5 to 7 Pulley and belt classification
Code Pulley and belt Applicable model
Q41 ø110 : M41 inch DDL-8700-7
* Pulley diameter: outer diameter is indicated.
3. MODEL CONSTRUCTION
9 Destination spec. classification
A Standard, Hong Kong, Singapore
B Europe
D America (including LA)
G China
10 Accessory spec.
classification
A Standard
11 Delivery voltage
classification
4 200 to 240V
(Caution) 1. Power consumption is the mean power consumption when SC-500 is mounted on DDL-8700
in accordance with the operating conditions JUKI settles.
2. Power consumption varies in accordance with the operating conditions and the machine
head on which SC-500 is mounted. So, be careful.
3. There are cases where the momentary maximum power consumption is 1.5 times or more
than the mean power consumption.
2. OUTLINE
(2) M-50
Servo motor for SC-500 (for export)
1 2 3 4 5 6 7 8 9 10 11
S C 5 0 0 - A A 4
1 2 3 4 5 6 7 8 9 10 11
M 5 0 D - A 4