Page #23 background imageLoading...
Page #23 background image
– 21 –
ENGLISH
8
Adjustment of the quantity of light of LED lamp ( )
Used to adjust the quantity of light of LED lamp (optional)
Setting range : 0 to 100%
9
Optical sensor function ( )
: Optical sensor function is disabled.

: After the optical sensor input, the sewing machine is stopped after the sewing of the number
of stitches set with
!2
( ).
* This function is enabled when the optical sensor is set with function setting No. 12.
!0
Optical sensor lter function ( )
: Optical sensor lter function is disabled.

: After the optical sensor detection, the input is delayed until the sewing machine has complet-
ed the sewing of the number of stitches set with
!1
( ).
* This function is enabled when the optical sensor is set with function setting No. 12.
!1
Number of stitches for the optical sensor lter ( )
 
Used to set the number of stitches for delaying the time at which the optical sensor input status takes effect.
Setting range: 0 to 99 stitches
* This function is enabled when the optical sensor is set with function setting No. 12.
!2
Number of stitches to stop the optical sensor ( )
Used to set the number of stitches to be sewn from the optical sensor input to the stop of the sewing machine.
Setting range: 0 to 99 stitches
* This function is enabled when the optical sensor is set with function setting No. 12.
(Caution) If a small number is set, the sewing machine may not be stopped within the set number of
stitches depending on the number of revolutions of the sewing machine.
!3
Number of times of optical sensor detection ( )
The sewing machine stops every time the optical sensor input is turned ON and carries out automatic
thread trimming when the set number of times is reached.
Setting range: 1 to 15 times
* This function is enabled when the optical sensor is set with function setting No. 12.
!4
Pedal depressing speed limiting function ( )
This function limits the pedal depressing speed at the time of the optical sensor input.
0 : The function is disabled.
1 : Fixed at the one-shot speed (function setting No. 38)
2 : Limited to the one-shot speed (function setting No. 38)
3 : When the optical sensor is enabled, the sewing machine runs under the automatic mode upon de-
press on the pedal.
* This function is enabled when the optical sensor is set with function setting No. 12.