Cleaning / repairing the unit
26
15
A
M
P
Circulator: Mains circuit breakers (resettable) 15 A
Cooling machine: Fuse T 10.0 A, dia.5 x 20 mm
The mains fuses (8b) on the rear of the unit may easily be
exchanged as shown on the left.
Warning:
Before exchanging the fuses, turn off the mains power switch and
disconnect the power plug from the mains socket!
Only use fine fuses with a nominal value as specified.
Example:
Manufacturer Supplier Type Order No.
Wickmann Wickmann G- fuse insert
T10,0A 5x20 mm
No. 19195
8. Cleaning / repairing the unit
Caution:
Always turn off the unit and disconnect the mains cable from the
power source before cleaning the unit.
Prevent humidity from entering into the circulator.
Electrical connections and any other work must be performed by
qualified personnel only.
To maintain the full cooling performance, clean the condenser
from time to time.
Switch off the unit, disconnect mains power cable.
Hold the venting grid, pull out and remove.
Clean the ribbed condenser with a vacuum cleaner.
Replace the venting grid.
Switch on the unit.