EasyManua.ls Logo

Julabo F32-HE User Manual

Julabo F32-HE
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
16.09.2019
Operating Manual
English
Refrigerated and
Heating Circulators
air cooled
F25-HE
F32-HE
F34-HE
FP50-HE
water cooled
FPW50-HE
Original Operating Manual
1.951.2460-V7 09/19
www.calcert.com sales@calcert.com1.888.610.7664
0
5
10
15
20
25
30

Table of Contents

Other manuals for Julabo F32-HE

Question and Answer IconNeed help?

Do you have a question about the Julabo F32-HE and is the answer not in the manual?

Julabo F32-HE Specifications

General IconGeneral
BrandJulabo
ModelF32-HE
CategoryAir Conditioner
LanguageEnglish

Summary

1. Operating Manual

1.1. Intended Use

Defines the intended application of the circulators for temperature control in baths and external systems.

2. Operator Responsibility – Safety Recommendations

2.4. Technical Specifications

Provides detailed technical data, dimensions, power, and performance for various models.

3. Safety notes for the user

3.3. Safety recommendations

Lists crucial safety precautions for operation, installation, and maintenance to prevent injury or damage.

5. Preparations

5.1. Installation

Provides guidance on placing the unit, ventilation requirements, and refrigerant room space considerations.

5.3. Temperature application to external systems

Explains how to connect the circulator for temperature control of closed and open external systems.

6. Operating procedures

6.1. Power connection

Explains how to safely connect the unit to the power supply, emphasizing earthing and cable integrity.

6.2. Switching on/Start - Stop

Describes the process of turning the circulator on, performing self-tests, and starting/stopping operation.

6.2.2. Switching on the Cooling Machine

Details how to switch on the cooling machine and its automatic control based on temperature requirements.

8. Safety installations, warning functions

8.1. Excess temperature protection

Details the adjustment and function of the excess temperature safety device to prevent hazards.

8.1.1. Early warning system, low level protection

Explains the two-stage low level protection system and its audible/visual warnings.

8.2. Switch-over from warning to shutdown function

Describes how to configure warning signals to trigger a shutdown when limit values are exceeded.

8.3. Over and Sub temperature warning function

Explains how to set warning values for over and sub temperatures for sensitive applications.

9. MENU Menu functions

9.4. MENU CONFIG - Configuration of unit

Covers various unit configurations like remote control, auto-start, time/date, and factory reset.

9.4.1. Remote control via the serial interface

Details how to set up and use remote control via an RS232 serial interface.

9.5. MENU CONTROL – Control characteristics and parameters

Covers internal/external control settings and self-tuning options.

9.5.1. CONTROL – Control INTERNAL/EXTERNAL

Explains the switchover between internal and external temperature control and the connection of a Pt100 sensor.

9.7. MENU ATC - Absolut Temperature Calibration

Introduces Absolute Temperature Calibration to compensate for temperature differences between the circulator and a measuring point.

9.7.3. CALIBRATION TYPE: 1-/2-/3-POINT

Defines the type of ATC calibration (1, 2, or 3 points) and explains pairs of values.

9.7.4. Example: 3-point calibration for internal control

Provides a step-by-step example of performing a 3-point calibration for internal control.

10. Troubleshooting guide/error messages

Error messages

Lists and describes various error messages, their causes, and recommended actions.

12. Remote control

12.1. Setup for remote control

Guides on configuring interface parameters and connecting the unit for remote control.

12.2. Communication with a PC or a superordinated data system

Explains how the circulator communicates with a PC or data system in remote control mode.

12.5. Error messages

Lists and describes various error messages, their causes, and recommended actions.

15. Cleaning/repairing the unit